Elit logo e-Elit - leading
electronic and automation component
online distributor
Est En
Elit shopping basket
Items: Total:
0
€0.00
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!



Digital DC Input Module Diagnostic Flex, 16-ch., 10..31.2VDC, Allen-Bradley
Image is illustrative
Digital DC Input Module Diagnostic Flex, 16-ch., 10..31.2VDC, Allen-Bradley
Code: 1794-IB16D
Price (indicative)
€159.20  /pc
Manufacturer :
Availability:
21 days
Weight:
0.118 kg/pc
Volume:
0.0004 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Digital DC Input Module Diagnostic Flex, 16-ch., 10..31.2VDC, Allen-Bradley

DESCRIPTIONS
Flex™ Digital DC Input Module, Type: Diagnostic, Number Of Channels: 16 (Isolated), Input: On-State Voltage: 10 VDC (Minimum), 24 VDC Nominal, 31.2 VDC (Maximum), On-State Current: 2 MA (Minimum) At 10 VDC, 8.2 MA Nominal At 24 VDC, 12.1 MA (Maximum) At 31.2 VDC, Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA Min, Voltage Rating: 10 - 31.2 VDC, Isolation: 2121 VDC For 1 SEC Between User And System, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 12 AWG Stranded Copper Wire, Communication: EtherNet/IP, ControlNet, DeviceNet And Profibus DP, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.1 IN, Height: 1.8 IN, Temperature Rating: 32 - 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G, Shock: 50 G (Non-Operating), Response Time: Off To On/On To Off: 0.25, 0.5, 1, 2, 4, 8, 16, 32 MS, Default: 0.25 MS, Power Dissipation: 8.5 W At 31.2 VDC, Output Type: Current Sinking, Impedance: Input: 3.1 KOHM, Indicator: 16 Yellow ON/OFF Status (Field Side), 16 Red Diagnostic Status (Each Channel, Field Side), 1 Red Module Fault (Field Side), Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal/Power Ports, Keyswitch Position: 2, Bus Rating: 30 MA, Standard/Approvals: UL listed, CSA certified, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR, Application: For in-cabinets
SPECIFICATIONS
  • Item Name: Digital DC Input Module

  • Type: Diagnostic

  • Sub Brand: Flex™

  • Number Of Channels: 16 (Isolated)

  • Input: On-State Voltage: 10 VDC (Minimum), 24 VDC Nominal, 31.2 VDC (Maximum), On-State Current: 2 MA (Minimum) At 10 VDC, 8.2 MA Nominal At 24 VDC, 12.1 MA (Maximum) At 31.2 VDC, Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA Min

  • Voltage Rating: 10 - 31.2 VDC

  • Isolation: 2121 VDC For 1 SEC Between User And System

  • Enclosure: Open Type

  • Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ

  • Connection Cables: 12 AWG Stranded Copper Wire

  • Communication: EtherNet/IP, ControlNet, DeviceNet And Profibus DP

  • Mounting: DIN Rail, Panel

  • Length: 3.7 IN

  • Width: 2.1 IN

  • Height: 1.8 IN

  • Temperature Rating: 32 - 131 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G, Shock: 50 G (Non-Operating)

  • Response Time: Off To On/On To Off: 0.25, 0.5, 1, 2, 4, 8, 16, 32 MS, Default: 0.25 MS

  • Power Dissipation: 8.5 W At 31.2 VDC

  • Output Type: Current Sinking

  • Indicator: 16 Yellow ON/OFF Status (Field Side), 16 Red Diagnostic Status (Each Channel, Field Side), 1 Red Module Fault (Field Side)

  • Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal/Power Ports

  • Impedance: Input: 3.1 KOHM

  • Keyswitch Position: 2

  • Bus Rating: 30 MA

FEATURES

The FLEX I/O module plugs into the terminal base, connecting to the I/O bus and field devices. Since there is no direct wiring to the I/O module, modules can be removed and inserted under power, enabling to change modules without disturbing field wiring, other I/O modules, or system power. This eliminates costly downtime and the inefficiencies of restarting a system.

  • LED for each channel indicating status of: corresponding input device, output signal
  • Diagnostic (D) modules detect, indicate, and report the following faults: open input or output field devices or wiring, shorted output field devices, shorted input or output wiring, reverse polarity of user supply wiring
  • Standards: UL listed, CSA certified, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
  • Applications: For in-cabinets
 
 