Analog Input Module Flex™, 4-ch., 0.320µA/CNT, 24VDC
Image is illustrative
Analog Input Module Flex™, 4-ch., 0.320µA/CNT, 24VDC
Code: 1794-IF4I
Price (indicative)
€363.88  /pc
Manufacturer :
Availability:
14 days
Weight:
0.156 kg/pc
Volume:
0.0003 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Analog Input Module Flex™, 4-ch., 0.320µA/CNT, 24VDC, Allen-Bradley

DESCRIPTIONS
Flex™ I/O Analog Input Module, Number Of Channels: 4 (Isolated), Input: Input Current Terminal: 4 - 20 MA (User Configurable), 0 - 20 MA (User Configurable), Plus/Minus 20 MA (User Configurable), Input Voltage Terminal: Plus/Minus 10 V (User Configurable), 0 - 10 V (User Configurable), Plus/Minus 5 V (User Configurable), 0 - 5 V (User Configurable), Voltage Rating: 19.2 - 31.2 VDC (Includes 5% AC Ripple), 0.156 MV/CNT Unipolar, 0.313 MV/CNT Bipolar, Current Rating: 0.320 MICRO-A/CNT Unipolar, 0.640 MICRO-A/CNT Bipolar, External DC Power Supply Current: 80 MA At 24 VDC, Isolation: 120 V (Continuous), Basic Insulation Type, Channel To Channel, Channel To User, Channel To System And User Power To System When Used With 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, Or 1794-TB3TS, 250 V (Continuous), Basic Insulation Type, Channel To Channel, Channel To User, Channel To System And User Power To System When Used With 1794-TBN, Type Tested At 1000 VAC For 60 SEC, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.6 IN, Height: 3.7 IN, Temperature Rating: -4 To 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 5 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G, Response Time: Update Rate: 2.5/5.0/7.5 MS All Channels, Accuracy: Absolute Accuracy - Voltage Terminal: 0.1% Full Scale At 25 DEG C, Current Terminal: 0.1% Full Scale At 25 DEG C, Accuracy Drift With Temperature - Voltage Terminal: 0.0028% Full Scale/DEG C, Current Terminal: 0.0038% Full Scale/DEG C, Power Dissipation: 2 W At 31.2 VDC, Rejection Ratio: Normal Mode Rejection Ratio - Voltage Or Current Terminal: -3 DB At 12 HZ (300 HZ Conversion Rate), -80 DB At 50 HZ (300 HZ Conversion Rate), -3 DB At 6 HZ (150 HZ Conversion Rate), -80 DB At 60 HZ (150 HZ Conversion Rate), Common Mode Rejection Ratio: -120 DB At 50/60 HZ, Indicator: 1 Red/Green Power/Status Indicator, Bus Rating: Flexbus Voltage: 5 VDC, Flexbus Current: 50 MA, Resolution: 16 Bits - Unipolar, 15 Bits Plus Sign - Bipolar, Input Step Response: Step Response To 63% Of Full Scale: 1200 HZ Conversion Rate: 0.6 MS, 600 HZ Conversion Rate: 6.7 MS, 300 HZ Conversion Rate: 13.4 MS, 150 HZ Conversion Rate: 26.7 MS, Resistance: Input Resistance Voltage - Voltage Terminal: More Than 10 MOHM, Current Terminal: Less Than 100 OHM, Keyswitch Position: 3, Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Power Ports, Plus/Minus 2 KV Line-Earth(CM) On Shielded Signal Ports, Standard/Approvals: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, C-tick, TÜV certified, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR, RUS_PAT_APPR
SPECIFICATIONS
  • Item Name: Analog Input Module

  • Sub Brand: Flex™ I/O

  • Number Of Channels: 4 (Isolated)

  • Input: Input Current Terminal: 4 - 20 MA (User Configurable), 0 - 20 MA (User Configurable), Plus/Minus 20 MA (User Configurable), Input Voltage Terminal: Plus/Minus 10 V (User Configurable), 0 - 10 V (User Configurable), Plus/Minus 5 V (User Configurable), 0 - 5 V (User Configurable)

  • Voltage Rating: 19.2 - 31.2 VDC (Includes 5% AC Ripple), 0.156 MV/CNT Unipolar, 0.313 MV/CNT Bipolar

  • Current Rating: 0.320 MICRO-A/CNT Unipolar, 0.640 MICRO-A/CNT Bipolar, External DC Power Supply Current: 80 MA At 24 VDC

  • Isolation: 120 V (Continuous), Basic Insulation Type, Channel To Channel, Channel To User, Channel To System And User Power To System When Used With 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, Or 1794-TB3TS, 250 V (Continuous), Basic Insulation Type, Channel To Channel, Channel To User, Channel To System And User Power To System When Used With 1794-TBN, Type Tested At 1000 VAC For 60 SEC

  • Enclosure: Open Type

  • Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ

  • Mounting: DIN Rail, Panel

  • Length: 3.7 IN

  • Width: 2.6 IN

  • Height: 3.7 IN

  • Temperature Rating: -4 To 131 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 5 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G

  • Response Time: Update Rate: 2.5/5.0/7.5 MS All Channels

  • Accuracy: Absolute Accuracy - Voltage Terminal: 0.1% Full Scale At 25 DEG C, Current Terminal: 0.1% Full Scale At 25 DEG C, Accuracy Drift With Temperature - Voltage Terminal: 0.0028% Full Scale/DEG C, Current Terminal: 0.0038% Full Scale/DEG C

  • Power Dissipation: 2 W At 31.2 VDC

  • Indicator: 1 Red/Green Power/Status Indicator

  • Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Power Ports, Plus/Minus 2 KV Line-Earth(CM) On Shielded Signal Ports

  • Resolution: 16 Bits - Unipolar, 15 Bits Plus Sign - Bipolar

  • Keyswitch Position: 3

  • Bus Rating: Flexbus Voltage: 5 VDC, Flexbus Current: 50 MA

  • Resistance: Input Resistance Voltage - Voltage Terminal: More Than 10 MOHM, Current Terminal: Less Than 100 OHM

  • Input Step Response: Step Response To 63% Of Full Scale: 1200 HZ Conversion Rate: 0.6 MS, 600 HZ Conversion Rate: 6.7 MS, 300 HZ Conversion Rate: 13.4 MS, 150 HZ Conversion Rate: 26.7 MS

  • Rejection Ratio: Normal Mode Rejection Ratio - Voltage Or Current Terminal: -3 DB At 12 HZ (300 HZ Conversion Rate), -80 DB At 50 HZ (300 HZ Conversion Rate), -3 DB At 6 HZ (150 HZ Conversion Rate), -80 DB At 60 HZ (150 HZ Conversion Rate), Common Mode Rejection Ratio: -120 DB At 50/60 HZ

FEATURES

FLEX I/O offers all the functions of larger rack-based I/O without the space requirements. Its cost effectiveness, flexibility, modularity, and reliability have made it the most popular distributed I/O platform with over 4 million modules sold. FLEX I/O helps eliminate multiple long wiring runs, reduces terminations per point, decreases engineering and installation costs and time, and substantially reduces downtime. It complements all processor platforms from Rockwell Automation for a distributed I/O solution. Conformally coated, extreme environment FLEX I/O products help to reduce panel costs and the need for additional heating/cooling equipment, resulting in lower installation and maintenance costs.

  • Reduced space - wire direct from sensor to terminal base and eliminate terminal strip
  • Functionality: 4- through 32-point modules offer functions of larger rack-based I/O
  • Increased productivity: easy configuration and setup of I/O modules using wizards speeds engineering and installation
  • Reduced downtime: removal and insertion under power (RIUP) and diagnostics
  • Operation in harsh environments: conformal coated and extreme environment rated modules
  • Network flexibility: communicates on EtherNet/IP, ControlNet, DeviceNet, and PROFIBUS DP
  • Improved plant operations: HART analog modules pass through HART data to asset management software or controller for improved plant operations
  • Use with 2-, 3-, and 4-wire input sensor field devices
  • 16-bit 2’s complement, left-justified
  • Standards: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, C-tick, TÜV certified, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR, RUS_PAT_APPR
  • Applications: For in-cabinets
 
 