Image is illustrative
|
Discrete Digital Output Module MicroLogix™, 16-ch., 24VDC, Allen-Bradley Code:
1762-OB16
Price (indicative)
Manufacturer
:
Availability:
ask for dd
|
Weight:
0.25 kg/pc
|
Volume:
0.0011 m3/pc
|
|
|
|
|
Discrete Digital Output Module MicroLogix™, 16-ch., 24VDC, Allen-Bradley
MicroLogix™ Digital Output Module, Type: Discrete, Number Of Channels: 16 (Isolated), Output: Off-State Leakage: 1 MA, On-State Current: 1 MA, On-State Voltage Drop: 1 VDC, Continuous Current Per Point: 0.5 A At 55 DEG C, 1 A At 30 DEG C, Continuous Current Per Module: 4 A At 55 DEG C, 8 A At 30 DEG C, Voltage Rating: 20.4 - 26.4 VDC, Isolation: Verified By One Of The Following Dielectric Tests: 1200 VAC For 1 SEC Or 1697 VDC For 1 SEC, 75 VDC Working Voltage (IEC Class 2 Reinforced Insulation), Enclosure: IP20, Rfi Suppression: Radiated: 10 V/M, 80 - 1000 MHZ, 80% Amplitude Modulation, 900 MHZ Keyed Carrier, Conducted: 10 V, 0.15 - 80 MHZ, Mounting: DIN Rail, Panel, Length: 1.59 IN, Width: 3.425 IN, Height: 3.543 IN, Temperature Rating: -32 To 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 10 - 500 HZ, 5 G, 0.030 IN Max Peak-To-Peak, 2 HR Per Axis, Shock - Operating: 30 G Panel Mounted, 3 Pulses Per Axis, Non-Operating: 50 G Panel Mounted, 3 Pulses Per Axis (40 G DIN Rail Mounted), Response Time: Signal Delay - Turn-On: 1 MS, Turn-Off: 1 MS, Power Dissipation: Heat Dissipation: 2.9 W At 30 DEG C, 2.1 W At 55 DEG C, Output Type: Current Sourcing, Surge Transient Immunity: 2 KV Common Mode, 1 KV Differential Mode, Surge Current: 2 A (Repeatability Is Once Every 2 SEC At 55 DEG C, Once Every Second At 30 DEG C For A Duration Of 10 MS), Indicator: LED, Bus Rating: Bus Current Draw: 175 MA At 5 VDC (0.88 W), Standard/Approvals: C/US UL listed, UL 508, UL 1604, CSA C22.2, file number 213, CE marked, class I, division 2, hazardous location, groups A, B, C, D, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR
|
|
Specifications
- Item Name: Digital Output Module
- Type: Discrete
- Sub Brand: MicroLogix™
- Number Of Channels: 16 (Isolated)
- Output: Off-State Leakage: 1 MA, On-State Current: 1 MA, On-State Voltage Drop: 1 VDC, Continuous Current Per Point: 0.5 A At 55 DEG C, 1 A At 30 DEG C, Continuous Current Per Module: 4 A At 55 DEG C, 8 A At 30 DEG C
- Voltage Rating: 20.4 - 26.4 VDC
- Isolation: Verified By One Of The Following Dielectric Tests: 1200 VAC For 1 SEC Or 1697 VDC For 1 SEC, 75 VDC Working Voltage (IEC Class 2 Reinforced Insulation)
- Enclosure: IP20
- Rfi Suppression: Radiated: 10 V/M, 80 - 1000 MHZ, 80% Amplitude Modulation, 900 MHZ Keyed Carrier, Conducted: 10 V, 0.15 - 80 MHZ
- Mounting: DIN Rail, Panel
- Length: 1.59 IN
- Width: 3.425 IN
- Height: 3.543 IN
- Temperature Rating: -32 To 131 DEG F
- Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 10 - 500 HZ, 5 G, 0.030 IN Max Peak-To-Peak, 2 HR Per Axis, Shock - Operating: 30 G Panel Mounted, 3 Pulses Per Axis, Non-Operating: 50 G Panel Mounted, 3 Pulses Per Axis (40 G DIN Rail Mounted)
- Response Time: Signal Delay - Turn-On: 1 MS, Turn-Off: 1 MS
- Power Dissipation: Heat Dissipation: 2.9 W At 30 DEG C, 2.1 W At 55 DEG C
- Output Type: Current Sourcing
- Indicator: LED
- Surge Transient Immunity: 2 KV Common Mode, 1 KV Differential Mode
- Surge Current: 2 A (Repeatability Is Once Every 2 SEC At 55 DEG C, Once Every Second At 30 DEG C For A Duration Of 10 MS)
- Bus Rating: Bus Current Draw: 175 MA At 5 VDC (0.88 W)
Features
The 1762 MicroLogix expansion I/O modules are compatible with MicroLogix 1100, MicroLogix 1200, and MicroLogix 1400 controllers. Install the expansion I/O modules to the right of the controller, either on a panel with two mounting screws or on a DIN rail. Use digital I/O modules in many combinations, up to the maximum supported by the controller. The current loading capacity of the controller’s built-in power supply may limit the actual number of I/O modules that can be connected to the controller.
Integrated high-performance I/O bus
Software keying to prevent incorrect positioning within the system
Finger-safe terminal blocks for I/O wiring
Label to record I/O terminal designations
Network support includes EtherNet/IP, DeviceNet, and DH-485 (local only)
Standards: C/US UL listed, UL 508, UL 1604, CSA C22.2, file number 213, CE marked, class I, division 2, hazardous location, groups A, B, C, D, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR
|
|
|
|