|
|
|
Image is illustrative
|
Hybrid Motor Starter ELR W3-230AC/500AC-2I, 1pcs/pck, Phoenix Code:
2297044
Price
Manufacturer
:
Availability:
21 days
|
Weight:
0.3269 kg/pc
|
Volume:
0.0006 m3/pc
|
|
|
|
|
Hybrid Motor Starter ELR W3-230AC/500AC-2I, 1pcs/pck, PhoenixDimensions
Width
|
22.5 mm
|
Height
|
107 mm
|
Depth
|
114 mm
|
Ambient conditions
Ambient temperature (operation)
|
-25 °C ... 70 °C (observe derating)
|
Ambient temperature (storage/transport)
|
-40 °C ... 80 °C
|
Maximum altitude
|
≤ 2000 m
|
Degree of protection
|
IP20
|
Device supply
Rated control circuit supply voltage US
|
230 V AC
|
Control supply voltage range
|
92 V AC ... 253 V AC
|
Rated control supply current IS
|
4 mA
|
Mains frequency
|
40/100 Hz
|
Type of protection
|
Surge protection
|
Input data
Input name
|
Control input right/left
|
Rated actuating voltage UC
|
230 V AC
|
Triggering voltage range
|
92 V AC ... 253 V AC
|
Rated actuating current IC
|
7 mA
|
Switching threshold
|
44 V AC (“0” signal)
|
|
85 V AC (“1” signal)
|
Switching level
|
< 5 V DC (For EMERGENCY STOP)
|
Typical response time
|
< 35 ms
|
Typical turn-off time
|
< 80 ms
|
Output data load output
Output name
|
AC output
|
Rated operating voltage Ue
|
500 V AC
|
Operating voltage range
|
42 V AC ... 550 V AC
|
Rated operating current Ie
|
2.4 A (AC-51)
|
|
2.4 A (AC-53a)
|
Mains frequency
|
50/60 Hz
|
Load current range
|
180 mA ... 2.4 A (see to derating)
|
Trigger characteristic in acc. with IEC 60947-4-2
|
Class 10A
|
Cooling time
|
20 min. (for auto reset)
|
Leakage current
|
0 mA
|
Residual voltage
|
< 0.3 V
|
Surge current
|
100 A (t = 10 ms)
|
Type of protection
|
Surge protection
|
Output data reply output
Output name
|
Acknowledge output
|
Note
|
Confirmation: floating change-over contact, signal contact
|
Contact type
|
1 changeover contact
|
Switching capacity according to IEC 60947-5-1
|
3 A (230 V, AC15)
|
|
2 A (24 V, DC13)
|
General
Motor starter type
|
Reversing starter
|
Switching frequency
|
≤ 2 Hz (Load-dependent)
|
Mounting position
|
Vertical (horizontal DIN rail)
|
Mounting type
|
DIN rail mounting
|
Assembly instructions
|
Can be aligned with spacing = 20 mm
|
Operating mode
|
100% operating factor
|
Maximum power dissipation
|
4.7 W
|
Minimum power dissipation
|
2.6 W
|
Operating voltage display
|
Green LED
|
Status display
|
Yellow LED
|
Indication
|
Red LED
|
Connection data
Connection name
|
Control circuits
|
Connection method
|
Screw connection
|
Stripping length
|
8 mm
|
Screw thread
|
M3
|
Conductor cross section solid
|
0.2 mm² ... 2.5 mm²
|
Conductor cross section flexible
|
0.2 mm² ... 2.5 mm²
|
Conductor cross section AWG
|
24 ... 14
|
Torque
|
0.5 Nm ... 0.6 Nm
|
|
5 lbf-in. ... 7 lbf-in.
|
Connection data 2
Connection name
|
Load circuit
|
Connection method
|
Screw connection
|
Stripping length
|
8 mm
|
Screw thread
|
M3
|
Conductor cross section solid
|
0.2 mm² ... 2.5 mm²
|
Conductor cross section flexible
|
0.2 mm² ... 2.5 mm²
|
Conductor cross section AWG
|
24 ... 14
|
Torque
|
0.5 Nm ... 0.6 Nm
|
|
5 lbf-in. ... 7 lbf-in.
|
Insulation characteristics
Rated insulation voltage
|
500 V
|
Rated surge voltage
|
6 kV
|
Overvoltage category
|
III
|
Degree of pollution
|
2
|
Designation
|
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
|
Insulation
|
Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
|
|
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
|
|
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
|
Designation
|
Isolation characteristics between the control input and control supply voltage to auxiliary circuit
|
Insulation
|
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
|
|
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
|
Standards and Regulations
Designation
|
Standards/regulations
|
Standards/regulations
|
DIN EN 50178
|
|
EN 60947
|
|
IEC 61508
|
|
ISO 13849
|
Conformance/approvals
Designation
|
ATEX
|
Identification
|
II (2) G [Ex e] [Ex d] [Ex px]
|
|
II (2) D [Ex t] [Ex p]
|
Certificate
|
PTB 07 ATEX 3145
|
Designation
|
UL approval
|
Certificate
|
NLDX.E228652
|
Designation
|
Safety Integrity Level (SIL, IEC 61508)
|
Identification
|
≤ 3
|
Additional text
|
Safe shutdown
|
Designation
|
Safety Integrity Level (SIL, IEC 61508)
|
Identification
|
2
|
Additional text
|
Motor protection
|
Designation
|
Performance Level (ISO 13849)
|
Identification
|
≤ e
|
Additional text
|
Safe shutdown
|
Designation
|
Category (ISO 13849)
|
Identification
|
≤ 3
|
Additional text
|
Safe shutdown
|
UL data
SCCR
|
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
|
|
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
|
FLA
|
2.4 A (500 V AC)
|
Group installation
|
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
|
|
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
|
Category code
|
NLDX
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 50 years
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27370905
|
ECLASS 11.0 |
27370905
|
ECLASS 4.0 |
27021100
|
ECLASS 4.1 |
27021100
|
ECLASS 5.0 |
27024000
|
ECLASS 5.1 |
27024000
|
ECLASS 6.0 |
27024000
|
ECLASS 7.0 |
27024002
|
ECLASS 9.0 |
27370905
|
ETIM
ETIM 2.0 |
EC001037
|
ETIM 3.0 |
EC001037
|
ETIM 4.0 |
EC001037
|
ETIM 6.0 |
EC001037
|
ETIM 7.0 |
EC001037
|
UNSPSC
UNSPSC 6.01 |
30211915
|
UNSPSC 7.0901 |
39121514
|
UNSPSC 11 |
39121514
|
UNSPSC 12.01 |
39121514
|
UNSPSC 13.2 |
25173902
|
UNSPSC 18.0 |
25173902
|
UNSPSC 19.0 |
25173902
|
UNSPSC 20.0 |
25173902
|
UNSPSC 21.0 |
25173902
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|